Standard compliance testing, Test items, Supportable certifications
Standards for Consumer Products
| International | CISPR | CISPR11 | CISPR14-1 | CISPR14-2 | CISPR15 |
|---|---|---|---|---|---|
| CISPR22 | CISPR24 | CISPR32 | CISPR35 | ||
| IEC | IEC61000-3-2 | IEC61000-3-3 | IEC61000-3-11 | IEC61000-3-12 | |
| IEC61000-4-2 | IEC61000-4-3 | IEC61000-4-4 | IEC61000-4-5 | ||
| IEC61000-4-6 | IEC61000-4-8 | IEC61000-4-11 | |||
| IEC61000-6-1 | IEC61000-6-2 | IEC61000-6-3 | IEC61000-6-4 | ||
| IEC61326-1 | IEC60601-1-2 | IEC60204-31 | IEC61131-2 | ||
| Europe | EN | EN55011 | EN55014-1 | EN55014-2 | EN55015 |
| EN55022 | EN55024 | EN55032 | EN55035 | ||
| EN61000-6-1 | EN61000-6-2 | EN61000-6-3 | EN61000-6-4 | ||
| EN61326-1 | EN60601-1-2 | EN 301 489-1 | EN 301 489-17 | ||
| Japan | - | J55011 | J55014-1 | J55015 | J55022 |
| J55032 | CISPR J15 | CISPR J32 | |||
| VCCI technical standards | JIS T 0601-1-2 | JEITA IT-3001A | JIS C 61000-3-2 | ||
| Electrical Appliance and Material Safety Act, Appendix Table 10 (Noise intensity) | |||||
| Electrical Appliance and Material Safety Act, Appendix Table 12 (J standard) | |||||
| USA | FCC | FCC Part15 Subpart B | |||
| FCC Part18 | |||||
Standards for Automotive Equipment
| International | CISPR | CISPR 25 | CISPR 12(Partial) | ||
|---|---|---|---|---|---|
| ECE | R10 | ||||
| ISO | ISO 7637-2 | ISO 7637-3 |
ISO 16750-2 (Section 4.6) | ||
| ISO 11452-2 | ISO 11452-3 | ISO 11452-4 | ISO 11452-5 | ||
| ISO 11452-8 | ISO 11452-9 | ISO 10605 | |||
| Japan | JASO | D 007 | D 008 | D 010 | D 011 |
| D 014-2(Section 4.6) | |||||
| USA | SAE | J1113-25 | |||
| China | - | GB/T36282(EV-Chamber) | |||
| Carmakers | - | Our testing lab covers many standards for carmakers. Please contact us for details. | |||
Testing for Consumer Products
Anechoic chamber(AC),Shield room(SR)
| Test item | Standard | Specifications︎ | AC 1 | AC 2 | SR 1 |
|---|---|---|---|---|---|
| Radiated emissions |
CISPR11,CISPR14-1, CISPR15,CISPR32 IEC61000-6-3,IEC61000-6-4, IEC60601-1-2 IEC61326-1,Electrical Appliance and Material Safety Act VCCI,FCC Part15, FCC Part18 |
9k–30MHz (60cm loop, 2m large loop) 30–1000MHz, 1–6GHz (Measurable Up to 40GHz) | ○ | ○ | × |
|
Power port Conducted emissions |
CISPR11,CISPR14-1, CISPR15,CISPR32 IEC61000-6-3,IEC61000-6-4, IEC60601-1-2 IEC61326-1,Electrical Appliance and Material Safety Act VCCI,FCC Part15, FCC Part19 |
9k–30MHz(applicable to Single and 3 phase) Max. 100A | ○ | ○ | ○ |
| Load terminal / Auxiliary terminal | CISPR14-1,Electrical Appliance and Material Safety Act | 150k-30MHz | ○ | ○ | ○ |
|
Communication/Wired network port Conducted emissions |
CISPR32,IEC61000-6-3, IEC61000-6-4 |
150k-30MHz ANN, Current probe | ○ | ○ | ○ |
| Noise power (Interference power) | CISPR14-1,Electrical Appliance and Material Safety Act | 30-300MHz | ○ | ○ | × |
| Harmonic currents | IEC61000-3-2,IEC61000-3-12 | Max. 40A | ○ | ○ | ○ |
| Flicker | IEC61000-3-3,IEC61000-3-11 | Max. 20A | ○ | ○ | ○ |
| Electrostatic discharge | IEC61000-4-2 | ±30kV | ○ | ○ | ○ |
| Radiated electromagnetic field | IEC61000-4-3 |
80–1000MHz, Max. 20V/m 1–6GHz, Max. 10V/m | ○ | ○ | ○ |
| Burst | IEC61000-4-4 |
Applied voltage level: ±5.0kV Max. AC 600V/63A, DC 125V/63A | ○ | ○ | ○ |
| Surge | IEC61000-4-5 |
Applied voltage level: ±15kV Max. AC 500V/50A, DC 125V/50A | ○ | ○ | ○ |
| Conducted disturbances | IEC61000-4-6 | 150kHz-80MHz_10V | ○ | ○ | ○ |
| Power frequency magnetic field | IEC61000-4-8 | 50/60Hz, Max 40A/m | ○ | ○ | ○ |
| Voltage Dips, Short Interruption | IEC61000-4-11 | Max. single phase 16A | ○ | ○ | ○ |
| Human exposure to electromagnetic fields | ICNIRP1998,IEC62233 | ELT-400(1Hz–400kHz) from Narda S.T.S. | ○ | ○ | ○ |
Testing for Automotive Equipment
Anechoic chamber(AC),Shield room(SR)
| Test item | Standard | Specifications︎ | AC3 | AC 4 | SR 2 |
|---|---|---|---|---|---|
| Radiated emissions |
CISPR25,ECE R10, JASO D008 | 150k-6GHz(8GHz) | ○ | ○ | × |
| Conducted emissions (V) |
CISPR25,ECE R10, JASO D008 | (9k)150k-108MHz | ○ | ○ | ○ |
| Conducted emissions © | CISPR25, JASO D008 | (9k)150k-245MHz(1000MHz) | ○ | ○ | ○ |
| Transient emissions | ISO7637-2 | Section 4.3 | ○ | ○ | ○ |
| Magnetic field emissions | - |
20Hz–500kHz (12cm loop) 9kHz–30MHz (60cm loop) | ○ | ○ | × |
| The antenna method (ALSE) | ISO11452-2, JASO D011 | 200M-6GHz_200V/m | ○ | ○ | × |
| Radar pulse | - |
1.2-1.4GHz_600V/m, 2.7-3.1GHz_600V/m | ○ | ○ | × |
| TEM cell |
ISO11452-3, JASO D011 | 10kHz-400MHz_200V/m | × | × | ○ |
| BCI |
ISO11452-4, JASO D011 | 100kHz-1GHz_200mA | × | ○ | ○ |
| TWC |
ISO11452-4, JASO D011 | 400MHz–3GHz, Level I–Ⅳ | × | ○ | ○ |
| Stripline |
ISO11452-5, JASO D011 | 10kHz-400MHz_200V/m | ○ | × | ○ |
| Immunity to magnetic fields |
ISO11452-8, JASO D011 |
DC_3000A/m, 15Hz-150kHz_1000-10A/m A Helmholtz coil (Level Ⅰ and Ⅱ) is available. | ○ | ○ | ○ |
| Immunity to portable transmitters |
ISO11452-9, JASO D011 | 3.5MHz-6GHz | ○ | ○ | × |
| Tri-Plate | SAE J1113-25 | 10kHz-1000MHz_200V/m | ○ | × | × |
|
Transient voltage Power fluctuation |
ISO7637-2 , ECE R10 , JASO D007, ISO 16750-2, Section 4.6 ISO7637-3 |
1,2a,2b,3a,3b,4,5a,5b CCC, DCC and ICC methods | ○ | ○ | ○ |
| Static electricity | ISO10605, JASO D010 |
Max. ±30kV 150pF, 330pF, 330Ω, 2kΩ supporting micro-gap discharge | ○ | ○ | ○ |
| Motor system | GB/T36282 |
Max. rotation speed: 12000rpm Max. torque: 400Nm High-voltage power supply: Max. DC750V / 500A | × | ○ | × |
Testing for Other Equipment
Anechoic chamber(AC),Shield room(SR)
| Test item | Standard | Specifications︎ | AC 1 | AC 2 | SR 1 |
|---|---|---|---|---|---|
| Shielding evaluation |
MIL-STD-285 compliant IEEE STD 299 compliant NDS C 0012B compliant |
Frequency range: Please contact us Opening dimensions: Max. 500×500mm | × | ○ | |
| KEC method |
Frequency range: 100kHz–1000MHz Opening dimensions: Please contact us | × | × | ○ | |
|
Noise visualizations (3D scanning) | ― | WM9500 from MORITA TECH Co., Ltd. | ○ | ○ | ○ |
Inquiry form for EMC solution services
Please use the following form for asking our EMC solution services, EMC centers and/or the technical details.
If you are a website member, you can easily ask inquiry after Login.
入力フォーム読み込み中...フォームが表示されない場合